AXIS#.EIP.TP.SOURCE2

Description

AXIS#.EIP.TP.SOURCE2 modifies and configures the associated axis’ second touch probe trigger source byte.

Context

For more information on the usage of touch probes, see AKD2G EtherNet/IP Touch Probes.

Usage

Values for
AXIS#.EIP.TP.SOURCE#
Note

-41 to -42

Z pulse for Axis 1 to 2

-31 to -35

Z pulse for Feedback 1 to 5:

  • No existing product currently supports Z pulses on FB 1, 2, 4 and 5, therefore the corresponding values may not exist.
  • X23 is optional, when not fitted FB 3 won’t be available, therefore the corresponding value may not exist.

-21 to -26

DIO1 to DIO6:

  • When X22 is not fitted, options -21 and -22 will not be valid.

  • When X23 is not fitted, options -23 to -26 will not be valid.

-1 to -12

DIN1 to DIN12: When X22 is not fitted options -9 to -12 will not be valid.

0

Reserved

1

DIN1. Fast Opto

2

DIN2. Fast Opto

3-4

Reserved

5

Valid if AXIS#.PL.FBSOURCE is using a feedback that supports a Z pulse.

6 to 255

Reserved

Versions

Action Version Notes
Implemented 02-11-03-000

General Information

Type

Read /Write

Units

N/A

Range

-32768 to 32767

Default Value

2

Data Type

Integer

Stored in Non-Volatile Memory

No

Variants Supported

EtherNet/IP drives: AKD2G-SPI

Industrial Ethernet Information

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

7571

1

7571 (0x1d93)

AXIS1.EIP.TP.SOURCE2

Signed16

Read/Write

Yes

73107

2

7571 (0x1d93)

AXIS2.EIP.TP.SOURCE2

Signed16

Read/Write

Yes